866-626-PUMP |
Torrium® Control Unit
The Davey Torrium® automatically adapts to changing conditions because it has an
in-built titanium mounted brain that can out-smart every-day problems.
The Torrium® is easy to install, needs no adjustment and has few
maintenance issues. It's unique ability to respond to changing
circumstances ensures a steady, reliable flow of water is virtually
guaranteed day after day, year after year.
 |
Torrium®
Control Unit
- Replacement control
head for Davey HS & B Series Booster Pumps
- Self adapting to
incoming pressure - no adjustment needed
- 1" NPT outlet threads
- Includes replacement
inlet coupler
|
|
#T70P/USAD |
220v 60Hz Torrium Controller |
$ CALL |
|
#T70Y/USAD |
110v 60Hz Torrium Contoller |
$ CALL |
The Torrium® measures the pump shut off head each time the
pump stops, and sets the cut-in pressure at 80% of shut-off head, so
that the consumer is unlikely to notice any pressure change when the
pump is switched on.
The Torrium® starts pump on pressure drop and stops pump on
low flow (~0.5 GPM), thus reducing pump cycling for constant and even
water pressure.
The Torrium® adapts each time the pump stops, thus allowing
the system to accommodate variations in pump performance or site
conditions.
Features:
- CONSTANT FLOW
- LOSS OF PRIME PROTECTION
- ADAPTIVE PRESSURE SWITCH
- SIMPLIFIED FAULT FINDING
- AUTO RETRY
Explanation of Features and Operation:
The Torrium® has a simple indicator and fault LED system.
Red constant means that the system is in standby. Green constant means
the pump is running.
Cistern Fill mode is activated when The Torrium® detects
frequent short cycling, such as may be encountered with a very slow
filling toilet cistern. The Torrium® will then ensure the
pump continues to operate for at least 2 minutes.
The Torrium® stops the pump in loss of prime circumstances
and activates the "loss of prime" LED indicator sequence (red LED
single flash per sequence), thus protecting the pump from dry run
damage and helping to identify installation faults.
When the Torrium® detects loss of prime, it waits 5
minutes, then goes into auto retry mode, whereby it will restart the
pump to see if prime can be re-established automatically. Auto retry
occurs at 5 minutes, 1 hour, 2, 4, 8, 16, and 32 hours.
If The Torrium® detects excessive electrical current, such
as when the pump motor is subjected to locked rotor or when someone
tries to manually override the Torrium® by holding in the
prime button, the Torrium® will shut the pump down and
indicate 2 red flashes per sequence.
Should the Torrium® detect low incoming voltage (below 90
volts for 115V model and below 180 volts for 220V model) it will allow
the pump to continue to operate if possible, but it will flash two red
flashes per sequence over the green run LED.
Water over-temperature cut-out fail safe protection provides a second
level of protection against loss of prime and/or closed head operation
and/or repetitive cycling for added security and longer life. If the
Torrium® detects water temperature above 158 degrees F it
will shut down the pump and flash 3 red LED flashes per sequence. Once
the water temperature has dropped to below 140 degrees F, The Torrium®
will allow the pump to restart.
Click here for
factory Torrium®
Data Sheet
|